Methane measurement is the first step in effective methane management
In-situ, real-time methane measurement for digestate and sludge. Accurate methane management in complex liquids is the first step in effective methane management.

Emily measures methane in liquids. She is the first real-time continuous measurement system able to accurately quantify both dissolved and entrained methane in complex fluids such as wastewater and sludge. Emily provides operators with immediate data that was previously inaccessible, enabling process optimisation, inform investment decisions and enabling emissions mitigation.

Emily is installed directly on the sample line, delivering continuous, real-time methane data from complex liquid streams.
Working range: 0–80 mg/litre
Accuracy: 5–10% (compared to lab GC)
Detection limit: 1 mg/litre
Response time: 5–15 minutes
Liquids: Up to 12% solids, foam, macro solids and sample pressures up to 2 bar